Polymer Innovation Blog

Practical tips and advice for polymer, innovation and product development professionals

Polymer Innovation
  • Home
  • eBooks
    • Polymers in Electronic Packaging
    • Rheology of Thermosets eBook
    • Practical Tips for Curing Thermosets
    • Thermoset Characterization
    • Dielectric Cure Monitoring of Thermosets
    • Introduction to Biopolymers and Bioplastics
  • Videos
    • Core Curriculum: 3 Part Video Series
    • Characterization of Thermosets: 4 Part Video Series
    • Advanced Thermoset Cure Kinetics: 3 Part Video Series
    • DSC of Polymers: 5 Part Video Series
    • Thermoplastics: 5 Part Video Series
  • Services
    • Consulting
    • Polymer Expert Witness
  • Learning Center
    • White Paper
  • Why Jeff?
    • Speaker Info
  • Contact
  • Subscribe
  • Members
    • Login
    • Logout

UV Curing of Thermosets Part 13: Using UV Rheology to Monitor Curing – 4

April 4, 2016 By Jeffrey Gotro 1 Comment

expanded region for the moduli crossoverIn the previous post the role of UV intensity at a constant exposure time was shown to have a large impact on the curing kinetics.  As the UV intensity increased, the time to gelation decreased from the faster chemical crosslinking in an acrylate pressure sensitive adhesive.  Additionally, the UV rheometer data also showed that the modulus at the gel point was approximately the same for three UV exposure intensities another indication that gelation for this type of UV curing mechanism is an iso-conversion point.  This can be seen in the figure on the left.

In practical applications, it is important to determine the correct UV dosage. 

UV dosage = I X t

  • I is the UV intensity (mW)
  • t is the exposure time (seconds)

To investigate the impact of UV intensity as a function of time, a series of experiments were run at constant UV intensity of 30mW with the exposure time varied from 30 seconds to 240 seconds.  Figure 1 shows how the dynamic storage and loss moduli (G’ and G” respectively) change as a function of time.

Effect of UV exposure doseFigure Courtesy of TA Instruments

Figure 1. Dynamic Moduli as a function of time for various exposure times at a constant 30mW intensity.

The UV exposure causes a rapid increase in both the storage and loss moduli indicating rapid crosslinking due to generation of free radicals by the photoinitiators.  After 30 seconds of UV exposure, the storage modulus, G’ reaches a plateau of approximately 3 x 106 Pa (green curve in Figure 1).  This corresponds to a UV dosage of 900 mJ (0.9 Joules).  With a 60 second exposure time (1.8 Joules), the storage modulus, G’ reaches a plateau of approximately 5.5 x 106 Pa (red curve in Figure 1). At exposure times less than 60 seconds, there is not enough UV dosage to fully cure the acrylate PSA evaluated here.  Increasing the exposure to 120 seconds or longer yields approximately the same storage modulus after 200 seconds of reaction time.  In Figure 1, note that all of the storage moduli curves reach the same value (dark blue top curve in Figure 1) for exposure times of greater than or equal to 120 seconds.  Inspection of the data in Figure 1 indicates it would is difficult to determine the exact role of UV dose on the final storage moduli.  In order to evaluate the impact of UV dose the dynamic storage moduli, G’ at full cure (the asymptotic values in Figure 1) was plotted as a function of UV dosage in Joules in the Figure 2.

impact of UV dose on final modulusFigure Courtesy of TA Instruments

Figure 2. Final dynamic storage modulus (G’) as a function of UV dosage in Joules

As can be observed in Figure 2, the UV dose plays a strong role in developing the fully cured storage modulus. The UV dose represents the total amount of energy applied to the sample. In Figure 2, the storage moduli for each UV dose continues to increase with UV dose until a minimum of 6 Joules is applied.  The UV rheometer experiments indicated for the acrylate PSA in this example, a UV dose of at least 6 Joules would be required to achieve a fully cured adhesive.

In the last four posts we have demonstrated the utility of using a specially modified rheometer to follow the rheological changes during UV exposure.  There are several commercially available instruments with UV parallel plate geometries for these types of experiments. In the next series of posts we will explore the use of UV Differential Scanning Calorimetry (UV-DSC) to investigate the curing kinetics of UV cured polymers.

 

Share on LinkedIn Share

Filed Under: Uncategorized

« UV Curing of Thermosets Part 12: Using UV Rheology to Monitor Curing – 3
UV Curing of Thermosets Part 14: Using UV DSC to Monitor Curing – 1 »

Leave a Reply

Your email address will not be published. Required fields are marked *

Polymer Innovation Blog

I’m Dr. Jeff Gotro and welcome to the Polymer Innovation Blog. Over the last 40 years I have been involved in polymer research, along with product and process development. I acquired invaluable experience working for IBM, AlliedSignal, Honeywell, Ablestik Labs (now Henkel) and in multiple consulting projects. In this blog, I (along with some guest contributors) will share our experiences, tips, and “tricks of the trade” to get more out of your innovation efforts and discuss new trends and technical advances in the polymer industry.
View Jeff Gotro, Ph.D., CMC's profile on LinkedIn

Innocentrix, LLC


Click to Visit Website

plastics expert witness
Click for More Information

Subscribe by Email

Search the Blog

Polymer Video Training

Visit our Video Store

Polymers in Electronic Packaging

polymers in electronic packaging Are you confused about what is electronic packaging? Have you ever wondered what type of polymers and polymer-based composites are used in electronics? Learn More...

Practical Tips for Curing Thermosets

practical tips for curing thermosets Have you ever had a question about the degree of cure or is your part fully cured after processing? Confused about what is gelation or how does vitrification impact thermoset curing? Learn More...

Rheology of Thermosets

rheology of thermosets Have you ever had a question about measuring the rheological properties of thermosets Didn’t know what is the right experimental approach to get the right rheological information? Learn More...

Dielectric Cure Monitoring of Thermosets

Dielectric Cure Monitoring of Thermosets Do you have a need for an in-situ cure monitor for a thermoset process but don’t know where to start? Are you confused about the terminology used in dielectric spectroscopy? Learn More...

Introduction to Biopolymers and Bioplastics

Introduction to Biopolymers and Bioplastics Would you like to know how sustainable are bio-based polymers? Or what is the market size and growth rate for bioplastics? Or have questions about the biomass supply chain? Learn More...

Thermoset Characterization

Thermoset Characterization Have you ever had a question about how to measure a physical property of a thermoset? Confused about what is gelation or how does vitrification impact thermoset curing profiles? Or wondered how to measure the glass transition temperature of an epoxy or polyester composite? Learn More...

Amazon.com Bookshelf

Robert's Rules of Innovation Thermal Analysis of Polymers Order

Copyright © 2025 Innocentrix, LLC · All Rights Reserved