Polymer Innovation Blog

Practical tips and advice for polymer, innovation and product development professionals

Polymer Innovation
  • Home
  • eBooks
    • Polymers in Electronic Packaging
    • Rheology of Thermosets eBook
    • Practical Tips for Curing Thermosets
    • Thermoset Characterization
    • Dielectric Cure Monitoring of Thermosets
    • Introduction to Biopolymers and Bioplastics
  • Videos
    • Core Curriculum: 3 Part Video Series
    • Characterization of Thermosets: 4 Part Video Series
    • Advanced Thermoset Cure Kinetics: 3 Part Video Series
    • DSC of Polymers: 5 Part Video Series
    • Thermoplastics: 5 Part Video Series
  • Services
    • Consulting
    • Polymer Expert Witness
  • Learning Center
    • White Paper
  • Why Jeff?
    • Speaker Info
  • Contact
  • Subscribe
  • Members
    • Login
    • Logout

Dielectric Cure Monitoring Part 4: Non-Isothermal Curing

February 9, 2015 By Jeffrey Gotro 1 Comment

microdielectric sensor and interdigitated comb electrodes - CopyIn this post we will cover dielectric cure monitoring during non-isothermal curing.  Since most thermoset processing is done using a non-isothermal temperature profile (such as the initial heating ramp during lamination and autoclave curing), it will be instructive to examine the dielectric response for temperature ramps.

In the following figure, the dielectric permittivity and dielectric loss factor (at multiple frequencies) are plotted as a function of temperature for a DGEBA epoxy (EPON 828, Tg= –17oC) in the vicinity of the glass transition (1). 

dielectric response during non isothermal curing of 828 and DDS

We present this data to show how the dielectric response changes in the vicinity of the glass transition, since this will be important in future posts where the curing of prepregs will be discussed. In the top figure, the permittivity below the glass transition has the same value independent of frequency.  As the temperature increases to near the Tg, the dipoles gain sufficient mobility and contribute to the permittivity.  Near the glass transition, the material changes from a glassy state to a liquid in this case.  As the epoxy is heated approaching the Tg, there is now sufficient segmental mobility to allow the dipoles to increase the permittivity, with the lowest frequency indicating the beginning of the glass transition.  Once through the glass transition temperature, the permittivity achieves the relaxed permittivity (see reference 1 for a more detailed explanation), and then slowly decreases with increasing temperature. 

The dielectric loss factor is more instructive for cure monitoring.  In the lower figure above, the loss factor shows two distinct regions.  The first is the frequency dependent dipolar relaxations occurring in the vicinity of the glass transition temperature.  As we will see in future posts, this will be a fingerprint for the glass transition temperature (and additionally for vitrification under the right conditions) during thermoset processing.

After the frequency dependent dipolar relaxations, with continued heating into the liquid region, the ionic conductivity then dominates.  This is noted by the red up arrow in the figure. Thus this clearly demonstrates the two components of the dielectric loss factor:

dielectric loss factor - Copy

Where the frequency dependent dipolar relaxations are noted by e”d  and the ionic conductivity is s.

In the next figure, the loss factor is plotted as a function of time for a non-isothermal cure profile noted by the dashed line.  This is a simulation of a lamination temperature profile for an epoxy laminating resin. 

dielectric loss factor for non isothermal FR4 curing

The resin is a B-staged epoxy prepreg.  During the initial heating, there isn’t a good dielectric signal.  This results from incomplete coverage of the inter-digitated comb electrodes.  Until the B-staged resin goes through it’s glass transition temperature, the resin doesn’t adequately cover the electrodes.  We will show in future posts how to eliminate this, but for now, let’s focus on the loss factor characteristics.

Initially, after the B-staged prepreg goes through the glass transition temperature, the resin softens as the temperature increases.  This is observed as an increase in the loss factor due to the more ion mobility (and s increasing).  After the initial softening, the resin begins to chain extend and crosslink.  The competing forces of the temperature dependent viscosity decrease and the viscosity increase due to curing, cause a maximum in the loss factor.  With further curing, the loss factor decreases and then settles into a plateau.  A few features to note:

  • There is a shoulder on the early part of the loss factor.  The shoulder is due to the frequency dependent dipolar relaxations as the resin transitions through Tg.
  • There is a frequency independent maximum in the loss factor that is dominated by the ionic conductivity
  • The magnitude of the loss factor maximum is controlled by the frequency (inverse relationship in the equation above).
  • For cure monitoring, one wants to choose the optimum frequency to get good cure profiles, but avoid electrode polarization (see reference 1 for more details)
  • The loss factor achieves a plateau after about 40 minutes.  Since the cure temperature in this case was well above the fully cured Tg (130oC), the material will be fully cured as indicated by the flat line, but the level of the loss factor will be high since the material is in the cured rubbery phase (Tcure > fully cured Tg). 

The next post will discuss the simultaneous measurement of the viscosity and the dielectric response. 

References:

1) S.D. Senturia and N. F. Sheppard, Advances in Polymer Science, Vol. 80, p. 1-48, 1986

Share on LinkedIn Share

Filed Under: Uncategorized

« Introducing the eBook Store
Dielectric Cure Monitoring Part 5: Simultaneous Measurement of Viscosity and Dielectric Loss Factor »

Leave a Reply

Your email address will not be published. Required fields are marked *

Polymer Innovation Blog

I’m Dr. Jeff Gotro and welcome to the Polymer Innovation Blog. Over the last 40 years I have been involved in polymer research, along with product and process development. I acquired invaluable experience working for IBM, AlliedSignal, Honeywell, Ablestik Labs (now Henkel) and in multiple consulting projects. In this blog, I (along with some guest contributors) will share our experiences, tips, and “tricks of the trade” to get more out of your innovation efforts and discuss new trends and technical advances in the polymer industry.
View Jeff Gotro, Ph.D., CMC's profile on LinkedIn

Innocentrix, LLC


Click to Visit Website

plastics expert witness
Click for More Information

Subscribe by Email

Search the Blog

Polymer Video Training

Visit our Video Store

Polymers in Electronic Packaging

polymers in electronic packaging Are you confused about what is electronic packaging? Have you ever wondered what type of polymers and polymer-based composites are used in electronics? Learn More...

Practical Tips for Curing Thermosets

practical tips for curing thermosets Have you ever had a question about the degree of cure or is your part fully cured after processing? Confused about what is gelation or how does vitrification impact thermoset curing? Learn More...

Rheology of Thermosets

rheology of thermosets Have you ever had a question about measuring the rheological properties of thermosets Didn’t know what is the right experimental approach to get the right rheological information? Learn More...

Dielectric Cure Monitoring of Thermosets

Dielectric Cure Monitoring of Thermosets Do you have a need for an in-situ cure monitor for a thermoset process but don’t know where to start? Are you confused about the terminology used in dielectric spectroscopy? Learn More...

Introduction to Biopolymers and Bioplastics

Introduction to Biopolymers and Bioplastics Would you like to know how sustainable are bio-based polymers? Or what is the market size and growth rate for bioplastics? Or have questions about the biomass supply chain? Learn More...

Thermoset Characterization

Thermoset Characterization Have you ever had a question about how to measure a physical property of a thermoset? Confused about what is gelation or how does vitrification impact thermoset curing profiles? Or wondered how to measure the glass transition temperature of an epoxy or polyester composite? Learn More...

Amazon.com Bookshelf

Robert's Rules of Innovation Thermal Analysis of Polymers Order

Copyright © 2025 Innocentrix, LLC · All Rights Reserved